HD(CP)2 long term observations, data of Meteorological data (near surface) (no. 00), by Supersite RAO, data version 00
Daily files of meteorological surface data containing air temperature, relative humidity, wind direction, wind speed, precipitation and air pressure from several sensor locations at the Falkenberg boundary layer field site (for details see descriptive instrument location).
Access
To get a year dataset please use one of the links below to download the wget script:
2013, 2014, 2015, 2016, 2017,
Dataset Author
Udo Rummel, udo.rummel@dwd.de, Institution: Deutscher Wetterdienst, Meteorologisches Observatorium Lindenberg / Richard-Assmann-ObservatoriumDescription
10-minute average (except precipitation: 10-minute sum) values at the end of the measurement interval. The data acquisition rate of (1) , (3), (5), and (7) is 1 Hz. The average (sum) values represent the corresponding parameter at sensor level. At levels without measurements of a specific parameter missing values of -999.0 are set at the corresponding position in the file. In daily dataset files following level 1 products are included: (1) Air temperature at sensor level (2m): average offset correction is applied (see instrument specifications). (2) Current air temperature quality flag: 0 (undefined_quality), 1 (missing_value), 2 (quality_bad), 3 (quality_dubious), 4 (value_is_interpolated), 5 (quality_good), processed with internal QA routines by Deutscher Wetterdienst (DWD) described by Beyrich and Adam (Berichte des Deutschen Wetterdienstes, 230, 55 pp., 2007). (3) Relative humidity at sensor level (2m): a nonlinear correction is applied (see instrument specifications). (4) Current relative humidity quality flag: see (2). (5) Wind direction at sensor level (10m). (6) Current wind direction quality flag: see (2). (7) Wind speed at sensor level (10m): The representative wind speed measurement is selected from the anemometers of 3 booms at the meteorological tower in dependence of the wind direction at the corresponding level. (8) Current wind speed quality flag: see (2). (9) Precipitation amount (1m): Based on an internal sampling rate of ~ 0.17 Hz, the Pluvio Ombrometer System determines a filtered (to prevent result falsification by e.g. wind influence) precipitation intensity every minute. No additional corrections were applied. (10) Current precipitation amount quality flag: see (2). (11) Air pressure (1m): The data acquisition rate is ~ 0.1 Hz. No additional corrections were applied. (12) Current air pressure quality flag: see (2).
Limitations: none
Provenance: Meteorological data of Richard-Assmann Observatory, Lindenberg (DWD)
Comments: The coordinates specify the position of the 99 m tower at the Falkenberg boundary layer field site, where the 10 m wind speed information originates from. 10 m wind direction as well as 2 m air temperature/humidity measurements are performed at a 10 m mast ~70 m south-south-east of the meteorological tower. Precipitation and air pressure sensors (each at 1 m measuring height) in turn are located in the container facility area ~90 m north-east of the tower.
Instrument 1
- Source: Vaisala: HMP45D PT100 (IEC751 1/3 DIN Class B)
- Descriptive Instrument location: The sensors are located at the Falkenberg boundary layer field site. PT100 and HUMICAP: about 90 m north-east of the 99 m tower. Wind sensors: mounted at the 10m level of the 99 m tower and at the top of the 10m mast, 70 m south-south-east of the 99 m tower. Richard-Assmann-Observatorium, Deutscher Wetterdienst (DWD)
Instrument 2
- Source: Vaisala: HMP45D (HUMICAP 180)
- Descriptive Instrument location: The sensors are located at the Falkenberg boundary layer field site. PT100 and HUMICAP: about 90 m north-east of the 99 m tower. Wind sensors: mounted at the 10m level of the 99 m tower and at the top of the 10m mast, 70 m south-south-east of the 99 m tower. Richard-Assmann-Observatorium, Deutscher Wetterdienst (DWD)
Instrument 3
- Source: R. M. YOUNG COMPANY: Wind Monitor-SE (Model 09101)
- Descriptive Instrument location: The sensors are located at the Falkenberg boundary layer field site. PT100 and HUMICAP: about 90 m north-east of the 99 m tower. Wind sensors: mounted at the 10m level of the 99 m tower and at the top of the 10m mast, 70 m south-south-east of the 99 m tower. Richard-Assmann-Observatorium, Deutscher Wetterdienst (DWD)
Instrument 4
- Source: Adolf Thies GmbH & Co: 4.33303.22.000 cup anemometer
- Descriptive Instrument location: The sensors are located at the Falkenberg boundary layer field site. PT100 and HUMICAP: about 90 m north-east of the 99 m tower. Wind sensors: mounted at the 10m level of the 99 m tower and at the top of the 10m mast, 70 m south-south-east of the 99 m tower. Richard-Assmann-Observatorium, Deutscher Wetterdienst (DWD)
Instrument 5
- Source: OTT Hydromet GmbH: Pluvio (DWD version)
- Descriptive Instrument location: The sensors are located at the Falkenberg boundary layer field site. PT100 and HUMICAP: about 90 m north-east of the 99 m tower. Wind sensors: mounted at the 10m level of the 99 m tower and at the top of the 10m mast, 70 m south-south-east of the 99 m tower. Richard-Assmann-Observatorium, Deutscher Wetterdienst (DWD)
Instrument 6
- Source: Vaisala PTB220A
- Descriptive Instrument location: The sensors are located at the Falkenberg boundary layer field site. PT100 and HUMICAP: about 90 m north-east of the 99 m tower. Wind sensors: mounted at the 10m level of the 99 m tower and at the top of the 10m mast, 70 m south-south-east of the 99 m tower. Richard-Assmann-Observatorium, Deutscher Wetterdienst (DWD)
Global information
- PID: de.koeln.rrzk/amd.de.sups/rao.mets00.l1.any
- Project: HD(CP)2
- Level: 1
- Updated version: 00
- File format: NETCDF3_CLASSIC
- Convention: CF-1.6
- Average File Size Uncompressed: 0.017 Mb
- File name: sups_rao_mets00_l1_any_v[VV]_[YYYYMMDDhhmmss].nc
- Start: 2013-01-01
- End: 2017-12-31
Variables
Name | Dimension | CF standard_name | long_name | Unit |
---|---|---|---|---|
hur | time, | relative_humidity | Relative Humidity At Sensor Level | 1 |
hur_flag | time, | relative_humidity status_flag | Current Relative Humidity Quality At Sensor Level | missing |
pa | time, | air_pressure | Air Pressure At Sensor Level | Pa |
pa_flag | time, | air_pressure status_flag | Current Air pressure Quality At Sensor Level | missing |
precip | time, | precipitation_amount | Precipitation amount | kg m-2 |
precip_flag | time, | precipitation_amount status_flag | Current precipitation_amount Quality | missing |
ta | time, | air_temperature | Air Temperature At Sensor Level | K |
ta_flag | time, | air_temperature status_flag | Current Air Temperature Quality At Sensor Level | missing |
wdir | time, | wind_from_direction | Wind Direction At Sensor Level | degree |
wdir_flag | time, | wind_from_direction status_flag | Current Wind Direction Quality At Sensor Level | missing |
wspeed | time, | wind_speed | Wind speed At Sensor Level | m s-1 |
wspeed_flag | time, | wind_speed status_flag | Current Wind Speed Quality At Sensor Level | missing |